Figure14.
Tag Data Position
Table4.
Tag Classification based on EPC Global Protocol
EPC
Class
Description Functionality
Remarks
0 Read Only Passive tags
Data can be written only once
during tag manufacturing and
read many times
1
Write Once and
Read only
Passive tags
Data can be written only once
by tag manufacturer or user and
read many times
2 Read/Write Passive tags
User can read/write data many
times
3 Read/Write
Semi-passive
tags
Can be coupled with on board
sensors for capturing parameters
like temperatures, pressure, etc.
4 Read/Write Active tags
Can be coupled with on board
sensors and act as radio wave
transmitter to communicate with
reader
ISO/IEC 18000 series
ISO & IEC have established Joint Technical Committee to address technology standards.
Within JTC -1, Subcommittee 31, Work Group 4 deals with RFID. ISO 15693 and ISO 18000
series provide air interface standards for communication between tag-reader and reader-tag at
LF, HF, UHF and microwave frequencies. These standards also specify parameters like data
encoding rules, data transmission rates, types of signal modulations and anti-collision protocols
[6], [7].
18000-1 Part 1 - Generic Parameters for the Air Interface for Globally Accepted
Frequencies
18000-2 Part 2 - Parameters for Air Interface Communications below 135 KHz
18000-3 Part 3 - parameters for Air Interface Communications at 13.56 MHz
18000-4 Part 4 - Parameters for Air Interface Communications at 2.45 GHz